- Categories
-
Soczewka 4-lustro HighMag, bez kryzy (VG4HMNF)
50% more image magnification than our classic G-4 Gonio enables more detailed viewing of the trabecular meshwork
The quantity in the package | 1 opak |
Shipping within | 2 dni |
Shipping price | The Lack Of |
The Availability Of | dostępny 8 opak |
Pełna oferta Volk Optical USA | |
The bar code | |
EAN |
Zamówienie telefoniczne: 22 651 82 85
4-Mirror, All-Glass Design
Ideal for Magnified Anterior Chamber Angle Viewing
-
Take your exams and procedures to the next level with G-4 High Mag Gonio Lens. Our state-of-the-art four mirror, all-glass design gives you 50% increased image magnification of trabecular meshwork over our classic G-4 Gonio. With superior optics and a Posner-style model, you can easily perform dynamic and indentation gonioscopy with a no flange version and laser trabeculoplasty with a flanged version. Choose from a large ring (28.5 mm) or small ring (25.5 mm) to suit your needs. You also have the option of a two-position handle (right/left handed).
- 4 x 64° mirror angles
- 1.50x image magnification
- 0.67x laser spot size
- 15 mm (flange) / 8.4 mm (no flange) contact diameter
- No Flange/No Fluid version is ideal for dynamic and indentation/compression gonioscopy
- Small ring option suits petite hands
- Posner style handle provides support
Part Number:
VG4HM (Flange, Large Ring)
VG4HMLNF (No Flange, Large Ring)
VG4HMSNF (No Flange, Small Ring)
VG4HMHAN2 (No Flange, 2-in-1 Handle - Posner style)
Mirror Angles | Image Magnification | Laser Spot Size | Contact Diameter |
4 x 64° | 1.50x | 0.67x |
Flange: 15 mm No Flange: 8.4 mm |
Safety Information
GONIOSCOPY LENSES:
Do not use a microfiber cloth, as over time these tend to collect dirt and dust which can damage the anti reflective coating on the lens.
Never use a device that shows any sign(s) of damage.
Failure to follow the point-of-use processing steps could adversely affect further decontamination steps.
Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established.
A thorough, manual cleaning process is recommended. Corrosive cleaning agents (i.e. acids, alkalines, etc) are not recommended. Detergent cleaning agents with neutral ph are recommended.
Do not use detergents that contain any type of emollients.
Wiping the lens with a microfiber cloth will cause lens damage. Be sure to use only a soft, lint-free
cotton cloth.
Ensure the device is completely submerged in the disinfectant solution for the entirety of the recommended or desired soak time. Do not allow the device to become unsubmerged from the disinfectant solution. Exposure to disinfectant solutions beyond the recommended soak time, and/or exposure to higher concentrations of disinfectant solution, will result in accelerated degradation of most Volk product.
Rings may discolor when exposed to Sodium Hypochlorite or Glutaraldehyde. To avoid further degradation please follow only the disinfection procedures indicated for these products in this document. This color change is purely cosmetic and will not affect the function of the lens.
Do not brush lens portion to avoid scratching. Use a soft, cotton cloth.
To avoid surface damage to contact lenses, NEVER clean the contact elements with alcohol, peroxide or acetone.
Do not use the lens when the contacting surface(s) show(s) any signs of damage.
Do not use the lens if the mirroring surface(s) show(s) any signs of damage before or during laser usage.
Do not attempt to use the lens if, for any reason, the image is unclear or unfocused.
Do not attempt to use the lens unless an adequate type and amount of coupling fluid is present between the cornea and the contacting lens surface.
Gonio lenses apart from vslt and rapid slt (vmslt) lenses are not suitable for slt (selective laser trabeculoplasty) procedure any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established care should be taken to avoid excessive pressure on the cornea as it may affect aqueous dynamics or cause injury.
To avoid lens surface damage never clean the classic 3 mirror lenses, mini 4 mirror lens, or slt lens contact element with alcohol, peroxide, or acetone. G-series lenses may be cleaned with these chemicals.
G-series gonio lenses are not recommended for eto sterilization due to mirror degredation.
To avoid product damage, never autoclave or boil volk gonio lenses.
To avoid product damage, never subject volk gonio lenses to sterrad sterilziation.
For use by trained personnel only.
Manufacturer details
Volk Optical INC.
7893 Enterprise Dr, Mentor
OH 44060 Mentor,
United States
+1 440-942-6161
volk@volk.com
Responsible person
Rudolf Riester GmbH
Bruckstrasse, 31
72417 Jungingen
Germany
+49747792700
pfister@riester.de