Soczewka VOLK 4-lustro seria "G", z kryzą (VG4)
Flanged version provides stability for laser trabeculoplastyl 4 mirror, Sussman style lens with unbeatable Volk optics enables high detail examination of the angle structures
Количество в упаковке | 1 Упаковка |
Высылка в течение | 2 dni |
Цена доставки | Отсутствует |
Наличие на складе | dostępny 1 Упаковка |
Pełna oferta Volk Optical USA | |
Штрих код | |
EAN |
Zamówienie telefoniczne: 22 651 82 85
Ideal for Viewing Anterior Chamber Angle
The G-4 Mirror Gonio Lens gives the most comprehensive view of the trabecular meshwork with minimal lens rotation with its four mirror, all-glass design. This Sussman style lens features unbeatable optics for high detail examination of the angle structures. Choose from our large (28.5 mm) or small ring (25.5 mm), 2-position handle (right/left handed), Posner-style models, or opt for our no flange model for dynamic and indentation gonioscopy. We also offer a flanged version for enhanced stability during laser trabeculoplasty.
- 4 x 64° mirror angles
- 1.0x image magnification
- 1.0x laser spot size
- 15 mm (flange) / 8.4 mm (no flange) contact diameter
- Allows for a quick exam with maximum patient comfort
- No Flange/No Fluid version is ideal for dynamic and indentation/compression gonioscopy
- Not recommended for SLT - we recommend the Volk Rapid SLT or SLT lens instead
Part Number:
VG4 (Flange, Large Ring)
VG4LNF (No Flange, Large Ring)
VG4SNF (No Flange, Small Ring)
VG4HAN2 (No Flange, 2-in-1 Handle - Posner style)
Mirror Angles | Image Magnification | Laser Spot Size | Contact Diameter |
4 x 64° | 1.0x | 1.0x |
Flange: 15 mm No Flange: 8.4 mm |
Информация по технике безопасности
GONIOSCOPY LENSES:
Do not use a microfiber cloth, as over time these tend to collect dirt and dust which can damage the anti reflective coating on the lens.
Never use a device that shows any sign(s) of damage.
Failure to follow the point-of-use processing steps could adversely affect further decontamination steps.
Any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established.
A thorough, manual cleaning process is recommended. Corrosive cleaning agents (i.e. acids, alkalines, etc) are not recommended. Detergent cleaning agents with neutral ph are recommended.
Do not use detergents that contain any type of emollients.
Wiping the lens with a microfiber cloth will cause lens damage. Be sure to use only a soft, lint-free
cotton cloth.
Ensure the device is completely submerged in the disinfectant solution for the entirety of the recommended or desired soak time. Do not allow the device to become unsubmerged from the disinfectant solution. Exposure to disinfectant solutions beyond the recommended soak time, and/or exposure to higher concentrations of disinfectant solution, will result in accelerated degradation of most Volk product.
Rings may discolor when exposed to Sodium Hypochlorite or Glutaraldehyde. To avoid further degradation please follow only the disinfection procedures indicated for these products in this document. This color change is purely cosmetic and will not affect the function of the lens.
Do not brush lens portion to avoid scratching. Use a soft, cotton cloth.
To avoid surface damage to contact lenses, NEVER clean the contact elements with alcohol, peroxide or acetone.
Do not use the lens when the contacting surface(s) show(s) any signs of damage.
Do not use the lens if the mirroring surface(s) show(s) any signs of damage before or during laser usage.
Do not attempt to use the lens if, for any reason, the image is unclear or unfocused.
Do not attempt to use the lens unless an adequate type and amount of coupling fluid is present between the cornea and the contacting lens surface.
Gonio lenses apart from vslt and rapid slt (vmslt) lenses are not suitable for slt (selective laser trabeculoplasty) procedure any serious incident that has occurred in relation to the device should be reported to the manufacturer and the competent authority of the member state in which the user and/or patient is established care should be taken to avoid excessive pressure on the cornea as it may affect aqueous dynamics or cause injury.
To avoid lens surface damage never clean the classic 3 mirror lenses, mini 4 mirror lens, or slt lens contact element with alcohol, peroxide, or acetone. G-series lenses may be cleaned with these chemicals.
G-series gonio lenses are not recommended for eto sterilization due to mirror degredation.
To avoid product damage, never autoclave or boil volk gonio lenses.
To avoid product damage, never subject volk gonio lenses to sterrad sterilziation.
For use by trained personnel only.